Top Sellers in Distribution Equipt - Load Centers & S. E. Equipment

   
Show  items per page    First Previous  Page   of  4  Next Last
LOAD CENTER GROUND BAR KIT
EATON
GBK5
5 CIRCUIT GROUND BAR
LENGTH 2.54 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 5 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER; GBK MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
BR1224L125G
1PH 125A LDCTR
MAIN LUG; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (12) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION B1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 16-3/4 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC; INCLUDES GROUND BAR

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
EATON
GBK10
10 TERM GRD BAR
LENGTH 4.29 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 10 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER; GBK MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
EATON
GBK21
21 CIRCUIT GRD BAR
LENGTH 8.14 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 21 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER FILLER PLATE
EATON
BRFP
FILLER PLATE
CIRCUIT BREAKER SPACE; POLE SPACE 1 INCH; USED ON BR SERIES LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
EATON
GBK13
13 CIRCUIT GROUND BAR
LENGTH 4.61 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 2 TERMINAL ((1) 1/8 TO 14 AWG OR (3) 10 TO 12 AWG), 9 TERMINAL ((1) 14 TO 1/0 AWG OR (3) 14 TO 10 AWG); USED ON BR SERIES LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
BR1224L125R
1PH 125A LDCTR
MAIN LUG; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (12) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION B1R; SIZE 14-5/16 INCH W X 5-3/16 INCH D X 16-3/4 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
BR2040L200
1P 200A LDCTR
MAIN LUG; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); (20) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION C2; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 23 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
LOAD CENTER NEUTRAL AND GROUND LUG
EATON
NL30
150A NEUTRAL LUG
GROUND/NEUTRAL LUG; QUANTITY 1; USED ON TYPE CH LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
CONVERTIBLE LOAD CENTER
EATON
BR816N200RF
1PH 200A LDCTR
CONVERTIBLE MAIN; 120/240 VAC; 200 AMPERE; 16 MAXIMUM CIRCUIT(S); (8) 1 INCH MAXIMUM SPACE(S); BW MAIN BREAKER; INTERRUPTING RATING 10000/22000/25000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BACK FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER, MAIN BREAKER), 1 AWG TO 300 KCMIL (ALUMINUM/COPPER, MAIN LUG); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION C3R; SIZE 14-5/16 INCH W X 5-3/16 INCH D X 25 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Convertible Load Centers

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
BR612L125RP
LDCTR 125A MLO 3R
MAIN LUG; 120/240 VAC; 125 AMPERE; 12 MAXIMUM CIRCUIT(S); (6) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 14 TO 1 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 7R; SIZE 11 INCH W X 3-9/16 INCH D X 13 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
3BR3042L200R
200A LOADCNTR
MAIN LUG; 208 VAC STAR/120 VAC, 240 VAC; 200 AMPERE; 42 MAXIMUM CIRCUIT(S); (30) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION G1R; SIZE 14-5/16 INCH W X 5-3/16 INCH D X 34-1/8 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Three Phase Main Lug Load Centers

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
EATON
GBK14
14 CIRCUIT GROUND BAR
LENGTH 5.69 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 14 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
BR48L125RP
LDCNTR 125A MLO 3R
MAIN LUG; 120/240 VAC; 125 AMPERE; 8 MAXIMUM CIRCUIT(S); (4) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 14 TO 1/0 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 7R; SIZE 11 INCH W X 3-9/16 INCH D X 13 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
MAIN CIRCUIT BREAKER LOAD CENTER
EATON
BR3040B200
1P 200A LDCTR
MAIN BREAKER; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); (30) 1 INCH MAXIMUM SPACE(S); BW MAIN BREAKER; INTERRUPTING RATING 10000 AMPERE; BONDED SPLIT NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION G1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
* E=Each, C=100, M=1000