Need Help? Call 530-895-8611  
   CED - CHICO GREENTECH   
View Cart CART  
 Shop by Category  ( Show All )

Back

Top Sellers in Distribution Equipt - Meter Sockets & Mounting Assemblies

   
Show  items per page    First Previous  Page   of  2  Next Last
TEST BLOCK BYPASS METER SOCKET
COOPER B-LINE
127TB
200A 7T SFTY SKT BOX
RING; SERVICE TYPE OVERHEAD/UNDERGROUND; CIRCUIT CONFIGURATION 3 PHASE 4 WIRE; 600 V; 200 AMPERE; TEST BLOCK BYPASS SWITCH; 7 JAW(S); (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (1 1/4 INCH-1-1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (2 INCH-2 1/2 INCH-3 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); WIRE SIZE 6 AWG TO 250 KCMIL (LINE/LOAD), 6 TO 1/0 AWG (NEUTRAL); NEMA 3R; SURFACE MOUNTING; SIZE 14 INCH W X 6 INCH D X 30 INCH H; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED

Show all:  Test Block Bypass Meter Sockets

 More Details
RESIDENTIAL METER BREAKER
EATON
MBE2040B200BTS
200A MB COMB SRV
RING; BW2200 10000 AMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT; SERVICE TYPE UNDERGROUND; 120/240 VAC; 200 AMPERE; 40 CIRCUIT(S); (20) 1 INCH POLE SPACE(S); DS, NO HUB; (1) (2 1/2-INCH-3 INCH-3-1/2 INCH-4 INCH) CONCENTRIC KNOCKOUT, (2) (1 1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (3/4 INCH-1 INCH-1-1/4 INCH-1-1/2 INCH) CONCENTRIC KNOCKOUT, (9) (1/2 INCH-3/4 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); SURFACE MOUNTING; APPROVAL UL 414; APPLICABLE STANDARD AEIC-EEI-NEMA (MSJ-7), EUSERC

Show all:  Residential Meter Socket Circuit Breaker Combinations

 Spec Sheet   |   More Details
CURRENT TRANSFORMER METERING MOUNTING BASE
COOPER B-LINE
6067HA
TFMR MOUNTING BASE
SURFACE; 600 V; 400 AMPERE; CIRCUIT CONFIGURATION 3 PHASE 3/4 WIRE; INTERRUPTING RATING 10 KILOAMPERE; 3 CURRENT TRANSFORMER(S); STUD TERMINAL; USED ON UTILITY/CURRENT TRANSFORMER METER; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
RESIDENTIAL METER BREAKER
EATON
MBER48B200BTS
BR METR BRKR "RANCH PANEL"
RING; 10 KILOAMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT; SERVICE TYPE OVERHEAD/UNDERGROUND; 120/240 V; 200 AMPERE; NO BYPASS SWITCH; 4 JAW(S); 8 CIRCUIT(S); 4 POLE SPACE(S); NEMA 3R; SURFACE MOUNTING; WIRE SIZE 300 KCMIL; SIZE 14.44 INCH W X 4.94 INCH D X 28.38 INCH H; APPROVAL UL 67, UL 414; INCLUDES MAIN BREAKER, FEED THROUGH LUG; BREAKER FEED TYPE BOTTOM/TOP; PROVISION 2 POLE 70 AMPERE BR/BRH/BRHH SECONDARY MAIN BREAKER; APPLICABLE STANDARD EUSERC

Show all:  Residential Meter Modules

 Spec Sheet   |   More Details
RESIDENTIAL METER BREAKER
EATON
MBE1224B100BTF
100A COMB MTR/CB
RING; 120/240 VAC; 100 AMPERE; 24 CIRCUIT(S); (12) 1 INCH POLE SPACE(S); DS, NO HUB; (1) (2 1/2-INCH-3 INCH-3-1/2 INCH-4 INCH) CONCENTRIC KNOCKOUT, (2) (1 1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (3/4 INCH-1 INCH-1-1/4 INCH-1-1/2 INCH) CONCENTRIC KNOCKOUT, (9) (1/2 INCH-3/4 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); FLUSH MOUNTING; APPROVAL UL 414; APPLICABLE STANDARD AEIC-EEI-NEMA (MSJ-7), EUSERC

Show all:  Residential Meter Socket Circuit Breaker Combinations

 Spec Sheet   |   More Details
METER SOCKET INTERCHANGEABLE UNIT HUB
MILBANK MFG CO
H30
3-IN HVY-DTY HUB
HEAVY DUTY LARGE R OPENING; 3 INCH CONDUIT

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
RESIDENTIAL METER SOCKET
COOPER B-LINE
011
100A 4TERM MTR SKT
RING; SERVICE TYPE OVERHEAD; CIRCUIT CONFIGURATION 1 PHASE 3 WIRE; 600 V; 125 AMPERE; NO BYPASS SWITCH; 4 JAW(S); (1) 1/2 INCH, (4) (1 INCH-1 1/4 INCH-1-1/2 INCH-2 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); WIRE SIZE 14 TO 2/0 AWG (LINE/LOAD/NEUTRAL); NEMA 3R; SURFACE MOUNTING; SIZE 8 INCH W X 4-5/8 INCH D X 12 INCH H; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED

Show all:  Residential Single Meter Sockets

 More Details
TEST BLOCK BYPASS METER SOCKET
COOPER B-LINE
117TB
100A 7T SFTY SKT BOX
RING; SERVICE TYPE OVERHEAD/UNDERGROUND; CIRCUIT CONFIGURATION 3 PHASE 4 WIRE; 600 V; 125 AMPERE; TEST BLOCK BYPASS SWITCH; 7 JAW(S); (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (5) (1 INCH-1 1/4 INCH-1-1/2 INCH-2 INCH) CONCENTRIC KNOCKOUT, (1) (1 1/4 INCH-1-1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); WIRE SIZE 14 TO 2/0 AWG (LINE/LOAD), 14 TO 1/0 AWG (NEUTRAL); NEMA 3R; SURFACE MOUNTING; SIZE 12 INCH W X 4-5/8 INCH D X 24 INCH H; APPROVAL UL 414; CIRCLE AW[T], B-LINE[R] BRAND; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED

Show all:  Test Block Bypass Meter Sockets

 More Details
RESIDENTIAL METER BREAKER
EATON
MBE1224B100BTS
MTR BRKR 100A MB 12/24CKT BTM/TOP
RING; 120/240 VAC; 100 AMPERE; 24 CIRCUIT(S); (12) 1 INCH POLE SPACE(S); DS, NO HUB; (1) (2 1/2-INCH-3 INCH-3-1/2 INCH-4 INCH) CONCENTRIC KNOCKOUT, (2) (1 1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (3/4 INCH-1 INCH-1-1/4 INCH-1-1/2 INCH) CONCENTRIC KNOCKOUT, (9) (1/2 INCH-3/4 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); SURFACE MOUNTING; APPROVAL UL 414; APPLICABLE STANDARD AEIC-EEI-NEMA (MSJ-7), EUSERC

Show all:  Residential Meter Socket Circuit Breaker Combinations

 Spec Sheet   |   More Details
METER BREAKER HUB
EATON
DS125H2
1-1/4IN HUB

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
METERING MAIN BREAKER
EATON
BW2175
2P 175A MAIN BKR
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 175 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; LINE TERMINAL TERMINAL; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489, CSA; USED ON ECB UNIT ENCLOSURE; CUTLER-HAMMER[R] BRAND; BW MODEL; INCLUDES 120 V SHUNT TRIP

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
METERING MAIN BREAKER
EATON
BW2100
100A 2P LDCTR PLG-IN CB
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; LINE TERMINAL TERMINAL; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489, CSA; USED ON ECB UNIT ENCLOSURE; CUTLER-HAMMER[R] BRAND; BW MODEL

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
TEST BLOCK BYPASS METER SOCKET
COOPER B-LINE
224MTB
200A 1PH MTR SKT&CB
RING, SELF CONTAINED METER MAIN; (1) 2 POLE 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CIRCUIT BREAKER MAIN DISCONNECT; SERVICE TYPE OVERHEAD; 120/240 V; 200 AMPERE; TEST BLOCK BYPASS SWITCH; 4 JAW(S); (2) AW, NO HUB; (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (1 1/4 INCH-1-1/2 INCH-2 INCH-2-1/2 INCH) CONCENTRIC KNOCKOUT, (3) (2 INCH-2 1/2 INCH-3 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S); NO PROVISION; NEMA 3R; SURFACE MOUNTING; WIRE SIZE 6 AWG TO 250 KCMIL (LINE/NEUTRAL); SIZE 14 INCH W X 6 INCH D X 48 INCH H; APPROVAL UL 67; CIRCLE AW[T], B-LINE[R] BRAND; MTB MODEL; APPLICABLE STANDARD ANSI C12.7; FINISH ANSI 61 GRAY ACRYLIC ELECTROCOATED; INCLUDES SNAP TYPE SEALING RING

Show all:  Test Block Bypass Meter Sockets

 Spec Sheet   |   More Details
METER SOCKET CLOSING PLATE
MILBANK MFG COMPANY
6003
PLSTC MTR CLOSING PLT
GRAY PLASTIC MATERIAL; MILBANK[R] BRAND

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
METER BREAKER HOUSE PANEL
EATON
HP404040SHA
400A RESI MM
RING; BWH2200 22 KILOAMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT; SERVICE TYPE UNDERGROUND; 120/240 VAC; 400 AMPERE; MANUAL BYPASS SWITCH; 40 CIRCUIT(S); 40 POLE SPACE(S); DS-H2 HUB; NEMA 3R; SURFACE MOUNTING; SIZE 30.084 INCH W X 7.218 INCH D X 44.057 INCH H; APPLICABLE STANDARD AEIC-EEI-NEMA MSJ-7, EUSERC

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
* E=Each, C=100, M=1000
First Previous  Page   of  2  Next Last
 
 


CED - CHICO GREENTECH 1210 W. 7TH ST. CHICO, CA 95928 | Tel: 530-895-8611 | Fax: 530-895-8624 | dwaldron@cedchico.com
Terms of Use | Terms and Conditions
3.5.4