Need Help? Call 530-895-8611  
   CED - CHICO GREENTECH   
View Cart CART  
 Shop by Category  ( Show All )

Back

Top Sellers in Distribution Equipt - Power Transformers & Conditioners

   
Show  items per page    First Previous  Page   of  2  Next Last
INDUSTRIAL CONTROL TRANSFORMER
EATON
C0250E2A
250VA TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110 V, 115 V, 120 V; 50/60 HZ; POWER RATING 250 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 4-1/2 INCH W X 4-3/8 INCH D X 3-13/16 INCH H; APPLICABLE STANDARD ANSI, NEMA ST-1, IEEE; APPROVAL UL, CSA; MTE MODEL; INCLUDES SECONDARY FUSE CLIP FOR 13/32 INCH X 1-1/2 INCH FUSE, PRIMARY JUMPER

Show all:  Encapsulated Industrial Control Transformers

 Spec Sheet   |   More Details
ELECTROSTATICALLY SHIELDED DRY TYPE TRANSFORMER
HAMMOND MFG CO
C1F003LES
3KVA TFMR
CONSTRUCTION ENCAPSULATED; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 3 KVA; 1 PHASE; TAPS (2) +2.5 PERCENT X (2) -2.5 PERCENT; TEMPERATURE RISE 115 DEG C; NEMA 3R; SIZE 10 INCH W X 7 INCH D X 13 INCH H; APPLICATION INDOOR/OUTDOOR; APPROVAL UL, CSA; HS MODEL

Show all:  Electrostatically Shielded Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
ENCAPSULATED DRY TYPE TRANSFORMER
HAMMOND MFG CO
C1F002LES
2KVA 1PH TFMR 480/240 X 120/240
CONSTRUCTION ENCAPSULATED; PRIMARY VOLTAGE 240 X 480 V; SECONDARY VOLTAGE 120/240 V; 60 HZ; POWER RATING 2 KVA; 1 PHASE; TEMPERATURE RISE 180 DEG C; WALL MOUNTING; NEMA 3R; SIZE 6.69 INCH W X 5.34 INCH D X 12-1/2 INCH H; APPLICATION INDOOR/OUTDOOR; APPROVAL UL, CUL; JEFFERSON[R] BRAND; APPLICABLE STANDARD ANSI, NEMA

Show all:  Non Ventilated Totally Enclosed Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
POWER SUPPLY
EATON
PSG240E
1PH 85-264V PWR SPLY

Show all:  Ac Power Supplies

 Spec Sheet   |   More Details
INDUSTRIAL CONTROL TRANSFORMER
EATON
C0150E2A
150VA TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110 V, 115 V, 120 V; 50/60 HZ; POWER RATING 150 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 3-3/4 INCH W X 4 INCH D X 3-3/16 INCH H; APPLICABLE STANDARD ANSI, NEMA ST-1, IEEE; APPROVAL UL, CSA; MTE MODEL; INCLUDES SECONDARY FUSE CLIP FOR 13/32 INCH X 1-1/2 INCH FUSE, PRIMARY JUMPER

Show all:  Encapsulated Industrial Control Transformers

 Spec Sheet   |   More Details
EATON
V48M28T7516
75KVA VNTD TFM 480X 120Y208V

Show all:  Energy Efficient Dry Type Transformers 600v Or Less

 More Details
EATON
WS59
TFM WEATHER SHIELD KIT

Show all:  Transformer Accessories

 More Details
EATON
V48M28T4516
45KVA VNTD TFM 480X120Y208

Show all:  Energy Efficient Dry Type Transformers 600v Or Less

 More Details
EATON
WS58
TFM WEATHER SHIELD KIT

Show all:  Transformer Accessories

 More Details
INDUSTRIAL CONTROL TRANSFORMER
EATON
C0500E2A
500VA TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110 V, 115 V, 120 V; 50/60 HZ; POWER RATING 500 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 5-1/4 INCH W X 5-1/2 INCH D X 4-3/4 INCH H; APPLICABLE STANDARD ANSI, NEMA ST-1, IEEE; APPROVAL UL, CSA; MTE MODEL; INCLUDES SECONDARY FUSE CLIP FOR 13/32 INCH X 1-1/2 INCH FUSE, PRIMARY JUMPER

Show all:  Encapsulated Industrial Control Transformers

 Spec Sheet   |   More Details
INDUSTRIAL CONTROL TRANSFORMER
EATON
C0050E2A
50VA TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110 V, 115 V, 120 V; 50/60 HZ; POWER RATING 50 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 3 INCH W X 3 INCH D X 2-9/16 INCH H; APPLICABLE STANDARD ANSI, NEMA ST-1, IEEE; APPROVAL UL, CSA; MTE MODEL; INCLUDES SECONDARY FUSE CLIP FOR 13/32 INCH X 1-1/2 INCH FUSE, PRIMARY JUMPER

Show all:  Encapsulated Industrial Control Transformers

 Spec Sheet   |   More Details
INDUSTRIAL CONTROL TRANSFORMER
EATON
C0075E2A
75VA TFMR
PRIMARY VOLTAGE 220 X 440 V, 230 X 460 V, 240 X 480 V; SECONDARY VOLTAGE 110 V, 115 V, 120 V; 50/60 HZ; POWER RATING 75 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 3 INCH W X 3-1/2 INCH D X 2-9/16 INCH H; APPLICABLE STANDARD ANSI, NEMA ST-1, IEEE; APPROVAL UL, CSA; MTE MODEL; INCLUDES SECONDARY FUSE CLIP FOR 13/32 INCH X 1-1/2 INCH FUSE, PRIMARY JUMPER

Show all:  Encapsulated Industrial Control Transformers

 Spec Sheet   |   More Details
POWER SUPPLY
EATON
PSG240F
24VDC 10A PWR-SPLY

Show all:  Ac Power Supplies

 Spec Sheet   |   More Details
INDUSTRIAL CONTROL TRANSFORMER
EATON
C0250E5E
250VA TFMR
PRIMARY VOLTAGE 200/220/440 V, 208/230/460 V, 240/480 V; SECONDARY VOLTAGE 23/110 V, 24/115 V, 25/120 V; 50/60 HZ; POWER RATING 250 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 4-1/2 INCH W X 5-1/4 INCH D X 3-13/16 INCH H; APPLICABLE STANDARD ANSI, NEMA ST-1, IEEE; APPROVAL UL, CSA; MTE MODEL; INCLUDES SECONDARY FUSE CLIP FOR 13/32 INCH X 1-1/2 INCH FUSE

Show all:  Encapsulated Industrial Control Transformers

 Spec Sheet   |   More Details
ENCAPSULATED TRANSFORMER
HAMMOND MFG CO
C1F015LES
1PH 15KVA 480-240 TFM

Show all:  Non Ventilated Totally Enclosed Dry Type Transformers 600v Or Less

 Spec Sheet   |   More Details
* E=Each, C=100, M=1000
First Previous  Page   of  2  Next Last
 
 


CED - CHICO GREENTECH 1210 W. 7TH ST. CHICO, CA 95928 | Tel: 530-895-8611 | Fax: 530-895-8624 | dwaldron@cedchico.com
Terms of Use | Terms and Conditions
3.5.4